CV test

From ChemWiki
Revision as of 10:38, 22 March 2023 by 141.52.96.111 (talk) (Created page with "{{Cyclic Voltammetry experiments |experiments={{Cyclic Voltammetry |anl=Ru(bpy)3 |anl conc=2 |redox potential=1,6;-3,3 |solv=DMA |solv vol=2 |electrolyte=NBu4BF4 |el conc=0.1...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

<ul><li>"negative to positive" is not in the list (IUPAC, US) of allowed values for the "Scan direction" property.</li> <!--br--><li>"Argon" is not in the list (nitrogen, argon, CO2, CO, O2, H2, none) of allowed values for the "Gas" property.</li> <!--br--><li>"glassy carbon disc" is not in the list (gold, silver, platinum, glassy carbon, boron doped diamond, pyrolytic carbon, copper, other) of allowed values for the "Working electrode" property.</li> <!--br--><li>"*pi" can not be assigned to a declared number type with value 1.</li> <!--br--><li>"Pt wire" is not in the list (gold, platinum, carbon, other) of allowed values for the "Counter electrode" property.</li> <!--br--><li>"Ag/Ag+ (AgNO3)" is not in the list (SCE, SHE, RHE, Ag/AgCl in KCl(sat.), Ag/AgCl in KCl(3M), Ag/AgCl in NaCl(sat.), Ag/AgCl in NaCl(3M), Ag/AgNO3 in MeCN, other) of allowed values for the "Reference electrode" property.</li></ul>
analyte anl conc [mM] reduction potential oxidation potential solvent solvent vol [ml] electrolyte electrolyte purity el conc [M] int ref comp scan rate [mv s-1] scan number potential window scan dir gas T [° C] condition [nm] WE WE surface area [mm²] CE RE Details include

Ru(bpy)3

2

1,6

-3,3

DMA

2

NBu4BF4

0.1

Fc+/Fc

100 5 -8 - 10 negative to positive Argon 25 450 glassy carbon disc 1*pi Pt wire Ag/Ag+ (AgNO3)