Form:Cyclic Voltammetry experiments: Difference between revisions

From ChemWiki
No edit summary
(Added to the wiki via WikiImport-Script.)
 
(20 intermediate revisions by 3 users not shown)
Line 12: Line 12:
{{{for template|Cyclic Voltammetry|multiple|embed in field=Cyclic Voltammetry experiments[experiments]}}}
{{{for template|Cyclic Voltammetry|multiple|embed in field=Cyclic Voltammetry experiments[experiments]}}}
{| class="formtable"
{| class="formtable"
! analyte (catalyst):
! analyte / analyte concentration [mM]:
| {{{field|anl|input type=combobox|property=Analyte|values from category=Molecule}}}
| {{{field|anl|input type=combobox|property=Analyte|values from url=molecule_lookup_analyte}}}
| {{{field|anl conc|input type=regexp|property=Analyte concentration|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*(\s+(M|mM|µM)?)?$/}}}
|-
|-
! analyte concentration [mM]:
! redox potential / E0,0 [V]:
| {{{field|anl conc|input type=regexp|property=Analyte concentration|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*$/}}}
| {{{field|redox potential|input type=redoxinput}}}
| {{{field|e0|input type=regexp|property=E0|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*(\s+(V)?)?$/}}}
|-
|-
! redox potential:
! solvent / solvent volume [ml]:
| {{{field|redox potential|input type=regexp|base type=string|message=Input value pairs according to the format description|regexp=/(^$)!(^(([+-]?([0-9]*\.)?[0-9]*)?,([+-]?([0-9]*\.)?[0-9]*)?)(;(([+-]?([0-9]*\.)?[0-9]*)?,([+-]?([0-9]*\.)?[0-9]*)?))*$)/}}}
| {{{field|solv|input type=combobox|property=Solvent A|values from url=molecule_lookup_solvent}}}
| {{{field|solv vol|input type=regexp|property=Solvent volume|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*(\s+(ml|l)?)?$/}}}
|-
|-
! solvent:
! electrolyte / electrolyte purity [%] / electrolyte concentration [M]:
| {{{field|solv|input type=combobox|property=Solvent A|values from category=Molecule}}}
| {{{field|electrolyte|property=Electrolyte|input type=combobox|values from url=molecule_lookup_electrolyte}}}
|-
| {{{field|electrolyte purity|property=Electrolyte purity|input type=regexp|regexp=/^([0-9]*\.)?[0-9]*(\s+(%)?)?$/}}}
! solvent volume [ml]:
| {{{field|el conc|input type=regexp|property=Electrolyte concentration|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*(\s+(M|mM|µM)?)?$/}}}
| {{{field|solv vol|input type=regexp|property=Solvent volume|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*$/}}}
|-
! electrolyte:
| {{{field|electrolyte|property=Electrolyte|input type=string}}}
|-
! electrolyte concentration [M]:
| {{{field|el conc|input type=regexp|property=Electrolyte concentration|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*$/}}}
|-
|-
! internal reference compound:
! internal reference compound:
| {{{field|int ref comp|property=Internal reference compound|input type=dropdown}}}
| {{{field|int ref comp|property=Internal reference compound|input type=combobox|values from url=molecule_lookup_irc}}}
|-
! scan rate [mv s-1]:
| {{{field|scan rate|input type=regexp|property=Scan rate|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*$/}}}
|-
|-
! scan number:
! scan rate [mV/s] / scan number:
| {{{field|scan rate|input type=regexp|property=Scan rate|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*(\s+(mV\/s)?)?$/}}}
| {{{field|scan number|input type=regexp|property=Scan number|base type=Number|message=Input a positive integer|regexp=/^[0-9]*$/}}}
| {{{field|scan number|input type=regexp|property=Scan number|base type=Number|message=Input a positive integer|regexp=/^[0-9]*$/}}}
|-
|-
! potential window:
! potential window [min, max]:
| {{{field|potential window|property=Potential window|input type=string}}}
| {{{field|potential window|property=Potential window|input type=regexp|regexp=/^[0-9](\.[0-9]+)?\s*,\s*[0-9](\.[0-9]+)?|$/|message=Input 2 numbers (comma-separated)}}}
|-
|-
! scan direction:
! scan direction:
Line 49: Line 43:
|-
|-
! gas (atmosphere):
! gas (atmosphere):
| {{{field|gas|property=Gas|input type=string}}}
| {{{field|gas|property=Gas|input type=combobox}}}
|-
|-
! temperature [° C]:
! temperature [°C]:
| {{{field|temp|input type=regexp|property=Temperature|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*$/}}}
| {{{field|temp|input type=regexp|property=Temperature|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*(\s+(°C)?)?$/}}}
|-
|-
! condition (wavelength [nm] or dark):
! condition (wavelength [nm] or dark):
| {{{field|cond|property=Condition|input type=string}}}
| {{{field|cond|property=Condition|input type=string}}}
|-
|-
! working electrode (type and material):
! working electrode / counter electrode / reference electrode:
| {{{field|WE|property=Working electrode|input type=string}}}
| {{{field|WE|property=Working electrode|input type=dropdown}}}
|-
| {{{field|CE|property=Counter electrode|input type=dropdown}}}
! WE surface area:
| {{{field|WE area|property=Working electrode surface area|input type=string}}}
|-
! counter electrode:
| {{{field|CE|property=Counter electrode|input type=string}}}
|-
! reference electrode:
| {{{field|RE|property=Reference electrode|input type=dropdown}}}
| {{{field|RE|property=Reference electrode|input type=dropdown}}}
|-
|-
|}
! WE surface area [mm²]:
{{{end template}}}
| {{{field|WE area|property=Working electrode surface area|input type=regexp|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*(\s+(mm²)?)?$/}}}
 
{{{for template|Oxidation Reduction Potential Pair|multiple|embed in field=Cyclic Voltammetry[oxiredu]}}}
{| class="formtable"
! E0 ox [V] (wip):
| {{{field|ox|property=Oxidation potential|input type=string}}}
|-
|-
! E0 red [V] (wip):
! include:
| {{{field|red|property=Reduction potential|input type=string}}}
| {{{field|include|input type=checkbox|property=Include}}} (check it when you want to include this investigation on topic pages)
|-
|-
|}
|}
;Details:
{{{field|details|input type=textarea|property=Details|message=Arbitrary extra information}}}
{{{end template}}}
{{{end template}}}


{{{standard input|save}}} {{{standard input|preview}}} {{{standard input|changes}}} {{{standard input|cancel}}}
{{{standard input|save}}} {{{standard input|preview}}} {{{standard input|changes}}} {{{standard input|cancel}}}
</includeonly>
</includeonly>

Latest revision as of 17:37, 17 January 2025

Add a new set of cyclic voltammetry experiments (a table in which each row describes one investigation):