Form:Cyclic Voltammetry experiments: Difference between revisions
From ChemWiki
Tareksaier (talk | contribs) No edit summary |
(Added to the wiki via WikiImport-Script.) |
||
(26 intermediate revisions by 3 users not shown) | |||
Line 13: | Line 13: | ||
{| class="formtable" | {| class="formtable" | ||
! analyte (catalyst): | ! analyte (catalyst): | ||
| {{{field|anl|input type=combobox|property=Analyte|values from | | {{{field|anl|input type=combobox|property=Analyte|values from url=molecule_lookup_analyte}}} | ||
|- | |- | ||
! analyte concentration [mM]: | ! analyte concentration [mM]: | ||
| {{{field|anl conc|input type=regexp|property=Analyte concentration|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*$/}}} | | {{{field|anl conc|input type=regexp|property=Analyte concentration|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*$/}}} | ||
|- | |- | ||
! redox potential: | |||
| | | {{{field|redox potential|input type=redoxinput}}} | ||
|- | |- | ||
! solvent: | ! solvent: | ||
| {{{field|solv|input type=combobox|property=Solvent A|values from | | {{{field|solv|input type=combobox|property=Solvent A|values from url=molecule_lookup_solvent}}} | ||
|- | |- | ||
! solvent volume [ml]: | ! solvent volume [ml]: | ||
Line 28: | Line 28: | ||
|- | |- | ||
! electrolyte: | ! electrolyte: | ||
| {{{field|electrolyte|property=Electrolyte|input type= | | {{{field|electrolyte|property=Electrolyte|input type=combobox|values from url=molecule_lookup_electrolyte}}} | ||
|- | |||
! electrolyte purity: | |||
| {{{field|electrolyte purity|property=Electrolyte purity|input type=regexp|regexp=/^([0-9]*\.)?[0-9]*$/}}} | |||
|- | |- | ||
! electrolyte concentration [M]: | ! electrolyte concentration [M]: | ||
Line 34: | Line 37: | ||
|- | |- | ||
! internal reference compound: | ! internal reference compound: | ||
| {{{field|int ref comp|property=Internal reference compound|input type= | | {{{field|int ref comp|property=Internal reference compound|input type=combobox|values from url=molecule_lookup_irc}}} | ||
|- | |- | ||
! scan rate [ | ! scan rate [mV s-1]: | ||
| {{{field|scan rate|input type=regexp|property=Scan rate|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*$/}}} | | {{{field|scan rate|input type=regexp|property=Scan rate|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*$/}}} | ||
|- | |- | ||
Line 42: | Line 45: | ||
| {{{field|scan number|input type=regexp|property=Scan number|base type=Number|message=Input a positive integer|regexp=/^[0-9]*$/}}} | | {{{field|scan number|input type=regexp|property=Scan number|base type=Number|message=Input a positive integer|regexp=/^[0-9]*$/}}} | ||
|- | |- | ||
! potential window: | ! potential window [min, max]: | ||
| {{{field|potential window|property=Potential window|input type= | | {{{field|potential window|property=Potential window|input type=regexp|regexp=/^[0-9](\.[0-9]+)?\s*,\s*[0-9](\.[0-9]+)?|$/|message=Input 2 numbers (comma-separated)}}} | ||
|- | |- | ||
! scan direction: | ! scan direction: | ||
Line 49: | Line 52: | ||
|- | |- | ||
! gas (atmosphere): | ! gas (atmosphere): | ||
| {{{field|gas|property=Gas|input type= | | {{{field|gas|property=Gas|input type=combobox}}} | ||
|- | |- | ||
! temperature [° C]: | ! temperature [° C]: | ||
Line 57: | Line 60: | ||
| {{{field|cond|property=Condition|input type=string}}} | | {{{field|cond|property=Condition|input type=string}}} | ||
|- | |- | ||
! working electrode | ! working electrode: | ||
| {{{field|WE|property=Working electrode|input type= | | {{{field|WE|property=Working electrode|input type=dropdown}}} | ||
|- | |- | ||
! WE surface area: | ! WE surface area [mm²]: | ||
| {{{field|WE area|property=Working electrode surface area|input type= | | {{{field|WE area|property=Working electrode surface area|input type=regexp|base type=Number|message=Input a positive number|regexp=/^([0-9]*\.)?[0-9]*$/}}} | ||
|- | |- | ||
! counter electrode: | ! counter electrode: | ||
| {{{field|CE|property=Counter electrode|input type= | | {{{field|CE|property=Counter electrode|input type=dropdown}}} | ||
|- | |- | ||
! reference electrode: | ! reference electrode: | ||
| {{{field|RE|property=Reference electrode|input type=dropdown}}} | | {{{field|RE|property=Reference electrode|input type=dropdown}}} | ||
|- | |- | ||
! Details: | |||
| {{{field|details|input type=textarea|property=Details|message=Arbitrary extra information}}} | |||
! | |||
| {{{field| | |||
|- | |- | ||
! | ! include: | ||
| {{{field| | | {{{field|include|input type=checkbox|property=Include}}} (check it when you want to include this investigation on topic pages) | ||
|- | |- | ||
|} | |} |
Latest revision as of 15:47, 30 August 2024
Add a new set of cyclic voltammetry experiments (a table in which each row describes one investigation):